Amicon® Ultra-15 Centrifugal Filter Unit, Ultracel-10 regenerated cellulose membrane, 15 mL sample volume, 10 kDa MWCO
In stock
Overview
General description
Amicon® Ultra 15 mL centrifugal devices with Ultracel® 10,000 Dalton molecular weight cutoff filters provide fast ultrafiltration, and reliable retention of macromolecules. For example, Cytochrome C (12.4 kDa) at 0.25 mg/ml initial concentration is retained at >95% .
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
Application
* Ultrafiltration with 10,000 Dalton molecular weight cutoff Ultracel® membrane.
* Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
* Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
* Concentration of dilute or pre-purified proteins from column eluents.
* Desalting, buffer exchange and protein dialysis.
Packaging
8, 24, 96 pkg
Features and Benefits
* Ultracel® regenerated cellulose membrane with 10 kDa NMWCO delivers retentate recovery of greater than 90%.
* Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10-15 minutes).
* Heat-sealed membrane minimizes downstream extractables.
* 100% integrity tested for reliable performance.
* Convenient sample monitoring with translucent housing and volume gradations.
* Direct pipettor sample access eliminates processing step to recover concentrate.
* High concentration factors of 80–100X.
Physical form
Color Code: Clear with pink cap
Product Code | UFC901096 |
---|---|
HSN Code | 84219900 |
Brand | Millipore |
Usually dispatched in | 2 Weeks |
Pack Size | 96 Pk |
General description
Amicon® Ultra 15 mL centrifugal devices with Ultracel® 10,000 Dalton molecular weight cutoff filters provide fast ultrafiltration, and reliable retention of macromolecules. For example, Cytochrome C (12.4 kDa) at 0.25 mg/ml initial concentration is retained at >95% .
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
Application
* Ultrafiltration with 10,000 Dalton molecular weight cutoff Ultracel® membrane.
* Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
* Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
* Concentration of dilute or pre-purified proteins from column eluents.
* Desalting, buffer exchange and protein dialysis.
Packaging
8, 24, 96 pkg
Features and Benefits
* Ultracel® regenerated cellulose membrane with 10 kDa NMWCO delivers retentate recovery of greater than 90%.
* Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10-15 minutes).
* Heat-sealed membrane minimizes downstream extractables.
* 100% integrity tested for reliable performance.
* Convenient sample monitoring with translucent housing and volume gradations.
* Direct pipettor sample access eliminates processing step to recover concentrate.
* High concentration factors of 80–100X.
Physical form
Color Code: Clear with pink cap
Write Your Own Review